W DOC AIRBUS | TSM A320F

Crossloading from FWC1 OEB DATABASE not Possible


TASK 31-51-00-810-808-A
Crossloading from FWC1 OEB DATABASE not Possible


1. Possible Causes
  • FWC-1 [1WW1]
  • wiring of the data bus between the FWC1 output bus and the FWC2 input bus
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-51-00-610-003
Crossload OEB REMINDER Data into FWCs using MCDUs.
ASM 315203
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-51-00-700-057-B
A. Do a new crossloading from the FWC1 AMM 31-51-00-610-003.
4. Fault Isolation
Subtask 31-51-00-810-057-B
A. If the UNABLE TO CROSSLOAD message comes into view on the ECAM2/OEB DATABASE UPDATE page:
   (1) If the fault continues:
  • do a check and repair the wiring of the data bus between the FWC1 output bus and the FWC2 input bus ASM 315203.
[Rev.8 from Aug 2018] 2026.04.04 04:30:11 UTC