W DOC AIRBUS | TSM A320F

Opposite FWC2 OEB DATABASE Data not Available


TASK 31-51-00-810-804-A
Opposite FWC2 OEB DATABASE Data not Available


1. Possible Causes
  • wiring between the FWC2 output bus and the FWC1 input bus
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 315205
3. Fault Confirmation
Subtask 31-51-00-700-053-B
A. Not applicable.
4. Fault Isolation
Subtask 31-51-00-810-053-B
A. If the NO RESPONSE message adjacent to the FWC2 indication comes into view on the ECAM1 OEB DATABASE page:
  • do a check and repair the wiring between the FWC2 output bus and the FWC1 input bus ASM 315205.
[Rev.8 from Aug 2018] 2026.04.04 04:30:10 UTC