Opposite FWC1 OEB DATABASE Data not Available
TASK 31-51-00-810-803-A
Opposite FWC1 OEB DATABASE Data not Available
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-51-00-700-052-B
Subtask 31-51-00-810-052-B
[Rev.8 from Aug 2018]
2026.04.04 04:30:10 UTC
Opposite FWC1 OEB DATABASE Data not Available
1. Possible Causes
- wiring between the FWC1 output bus and the FWC2 input bus
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 315205 |
Subtask 31-51-00-700-052-B
A. Not applicable.
4. Fault IsolationSubtask 31-51-00-810-052-B
A. If the NO RESPONSE message adjacent to the FWC1 indication comes into view on the ECAM2 OEB DATABASE page:
- do a check and repair the wiring between the FWC1 output bus and the FWC2 input bus ASM 315205.