W DOC AIRBUS | TSM A320F

Opposite FWC1 OEB DATABASE Data not Available


TASK 31-51-00-810-803-A
Opposite FWC1 OEB DATABASE Data not Available


1. Possible Causes
  • wiring between the FWC1 output bus and the FWC2 input bus
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 315205
3. Fault Confirmation
Subtask 31-51-00-700-052-B
A. Not applicable.
4. Fault Isolation
Subtask 31-51-00-810-052-B
A. If the NO RESPONSE message adjacent to the FWC1 indication comes into view on the ECAM2 OEB DATABASE page:
  • do a check and repair the wiring between the FWC1 output bus and the FWC2 input bus ASM 315205.
[Rev.8 from Aug 2018] 2026.04.04 04:30:10 UTC