W DOC AIRBUS | TSM A320F

Access to the ECAM2 OEB DATABASE not Possible


TASK 31-51-00-810-802-A
Access to the ECAM2 OEB DATABASE not Possible


1. Possible Causes
  • FWC-2 [1WW2]
  • wiring of the OEB pin programming signal from the FWC2 to ground
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 315228
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-51-00-700-051-B
A. Not applicable.
4. Fault Isolation
Subtask 31-51-00-810-051-B
A. On the ECAM2/FWC1/2-SDAC1/2-ECP page, if the OEB DATABASE indication is not shown:
   (1) Do an FWS LRU IDENTIFICATION of the FWC2(1WW2) and make sure, with the P/N, that the FWC2 has the OEB reminder function and that the DB/N (DATABASE Number) is shown.
     (a) If the FWC2 does not have the OEB reminder function:
     (b) If the FWC2 has the OEB REMINDER function and if there is no DB/N:
  • with the MCDU, do a check of the pin programming.
       1 If the parity is incorrect:
  • do a check and repair the wiring of the OEB pin programming signal from the FWC2 to ground AWM 315228.
[Rev.8 from Aug 2018] 2026.04.04 04:30:10 UTC