Access to the ECAM2 OEB DATABASE not Possible
TASK 31-51-00-810-802-A
Access to the ECAM2 OEB DATABASE not Possible
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-51-00-700-051-B
Subtask 31-51-00-810-051-B
[Rev.8 from Aug 2018]
2026.04.04 04:30:10 UTC
Access to the ECAM2 OEB DATABASE not Possible
1. Possible Causes
- FWC-2 [1WW2]
- wiring of the OEB pin programming signal from the FWC2 to ground
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AWM 315228 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-51-00-700-051-B
A. Not applicable.
4. Fault IsolationSubtask 31-51-00-810-051-B
A. On the ECAM2/FWC1/2-SDAC1/2-ECP page, if the OEB DATABASE indication is not shown:
(1) Do an FWS LRU IDENTIFICATION of the FWC2(1WW2) and make sure, with the P/N, that the FWC2 has the OEB reminder function and that the DB/N (DATABASE Number) is shown.
(a) If the FWC2 does not have the OEB reminder function:
(1) Do an FWS LRU IDENTIFICATION of the FWC2(1WW2) and make sure, with the P/N, that the FWC2 has the OEB reminder function and that the DB/N (DATABASE Number) is shown.
(a) If the FWC2 does not have the OEB reminder function:
- replace the FWC-2 [1WW2]
AMM 31-53-34-000-001 AMM 31-53-34-400-001.
- with the MCDU, do a check of the pin programming.
- do a check and repair the wiring of the OEB pin programming signal from the FWC2 to ground AWM 315228.