Access to the ECAM1 OEB DATABASE not Possible


TASK 31-51-00-810-801-A
Access to the ECAM1 OEB DATABASE not Possible


1. Possible Causes
  • FWC-1 [1WW1]
  • wiring of the OEB pin programming signal from the FWC1 to ground
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 315227
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-51-00-700-050-B
A. Not applicable.
4. Fault Isolation
Subtask 31-51-00-810-050-B
A. On the ECAM1/FWC1/2-SDAC1/2-ECP page, if the OEB DATABASE indication is not shown:
   (1) Do an FWS LRU IDENTIFICATION of the FWC1(1WW1) and make sure, with the P/N, that the FWC1 has the OEB reminder function and that the DB/N (DATABASE Number) is shown.
     (a) If the FWC1 does not have the OEB reminder function:
     (b) If the FWC1 has the OEB REMINDER function and if there is no DB/N:
  • with the MCDU, do a check of the pin programming.
       1 If the parity is incorrect:
  • do a check and repair the wiring of the OEB pin programming signal from the FWC1 to ground AWM 315227.