W DOC AIRBUS | TSM A320F

Loss of the DLRB signal to the FDIMU (DMU Part)


TASK 31-38-00-810-822-A
Loss of the DLRB signal to the FDIMU (DMU Part)


1. Possible Causes
  • wiring
  • ROUTING BOX-DATA LOADING [102TD]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-013
FDIMU AIDS Software Load Procedure with the PDL
ASM 313801
AMM 31-38-34-000-001
Removal of the Data Loading Routing Box (DLRB)
AMM 31-38-34-400-001
Installation of the Data Loading Routing Box (DLRB)
3. Fault Confirmation
Subtask 31-38-00-710-071-A ** ON A/C NOT FOR ALL
A. Load the AIDS software of the FDIMU AMM 31-36-00-710-013.
4. Fault Isolation
Subtask 31-38-00-810-071-A ** ON A/C NOT FOR ALL
A. If the fault is identified by the crew observation:

ACMS uploading is not possible.
   (1) Do a check for of the aircraft wiring between the ROUTING BOX-DATA LOADING [102TD] and DMU/FDIU (FDIMU) [10TV] ASM 313801:

  • A/32 (102TD) to pin AA/14G (10TV).

   (2) Do a check for of the aircraft wiring between the DMU/FDIU (FDIMU) [10TV] and the ROUTING BOX-DATA LOADING [102TD] :
     (a) pin AB/11C, 11D (10TV) to the pin A/49, 16 (102TD).
     (b) pin AA/11C, 11D (10TV) to the pin B/17, 33 (102TD).
   (3) if the fault continues:

Subtask 31-38-00-710-072-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:30:10 UTC