Loss of the MDDU Interface with the CFDIU
TASK 31-38-00-810-818-A
Loss of the MDDU Interface with the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-38-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-38-00-810-067-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:10 UTC
Loss of the MDDU Interface with the CFDIU
1. Possible Causes
- MDDU [1TD]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-38-00-740-002 | BITE Test of the Multipurpose Disk Drive Unit (MDDU) |
| ASM 313801 | |
| AMM 31-38-22-000-001 | Removal of the MDDU |
| AMM 31-38-22-400-001 | Installation of the MDDU |
Subtask 31-38-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-38-00-810-067-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU(1TW)/MDDU(1TD):
(1) Replace the MDDU [1TD] AMM 31-38-22-000-001 and AMM 31-38-22-400-001.
(2) If the fault continues:
Subtask 31-38-00-740-065-A ** ON A/C NOT FOR ALL (1) Replace the MDDU [1TD] AMM 31-38-22-000-001 and AMM 31-38-22-400-001.
(2) If the fault continues:
- do a check and repair the wiring from the MDDU (1TD) connector A/24, 25 to the first terminal block 1813VT ASM 313801.
B. Do the test given in Para. 3.A.