W DOC AIRBUS | TSM A320F

Loss of the DLRB Signal to the DMU


TASK 31-38-00-810-806-A
Loss of the DLRB Signal to the DMU


1. Possible Causes
  • wiring
  • ROUTING BOX-DATA LOADING [102TD]
  • DMU [1TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313801
AMM 31-38-34-000-001
Removal of the Data Loading Routing Box (DLRB)
AMM 31-38-34-400-001
Installation of the Data Loading Routing Box (DLRB)
3. Fault Confirmation
Subtask 31-38-00-710-059-A ** ON A/C NOT FOR ALL
A. Do the loading of the correct data base of the DMU (Ref. AMM 31-36-00, P. Block 201).
4. Fault Isolation
Subtask 31-38-00-810-055-A ** ON A/C NOT FOR ALL
A. If the fault is identified by the crew observation:

DMU uploading is not possible.
   (1) Do a check for of the aircraft wiring between the ROUTING BOX-DATA LOADING [102TD] and DMU [1TV] ASM 313801:

  • A/32 (102TD) to pin AA/14G (1TV).

   (2) Do a check for of the aircraft wiring between the DMU [1TV] and the ROUTING BOX-DATA LOADING [102TD] :
     (a) pin AB/11C, 11D (1TV) to the pin A/ 49, 16 (102TD).
     (b) pin AA/11C, 11D (1TV) to the pin B/ 17, 33 (102TD).
   (3) if the fault continues:

Subtask 31-38-00-710-060-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:30:08 UTC