FDIMU Receives No Data from MCDU 1 or MCDU 2
TASK 31-36-00-810-918-A
FDIMU Receives No Data from MCDU 1 or MCDU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-208-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-132-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:06 UTC
FDIMU Receives No Data from MCDU 1 or MCDU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-70-00-710-001 | Operational Test of the Multipurpose Control and Display Unit (MCDU) |
| AMM 31-36-00-740-012 | Test of the Flight Data Interface and Management Unit (FDIMU) |
| ASM 313601 | |
| AMM 31-36-34-000-002 | Removal of the FDIU/DMU (FDIMU) |
| AMM 31-36-34-400-002 | Installation of the FDIU/DMU (FDIMU) |
Subtask 31-36-00-740-208-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test AMM 31-36-00-740-012.
4. Fault IsolationNOTE: Make sure that the circuit breakers 5TV, 11CA1, 11CA2 on the panel 121VU and 11CA1 on the panel 49VU are closed during the test.
Subtask 31-36-00-810-132-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
Subtask 31-36-00-740-209-A ** ON A/C NOT FOR ALL - MCDU1 (3CA1) / FDIMU (10TV)
- MCDU2 (3CA2) / FDIMU (10TV)
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
- do a check and repair the wiring from the MCDU-1 [3CA1] or MCDU-2 [3CA2] to the DMU/FDIU (FDIMU) [10TV] ASM 313601:
MCDU 1 Connector A/27 to FDIMU Connector AA/11A
MCDU 1 Connector A/28 to FDIMU Connector AA/11B
MCDU 1 Connector A/11 to FDIMU Connector AA/11E
MCDU 1 Connector A/12 to FDIMU Connector AA/11F
or
MCDU 2 Connector A/27 to FDIMU Connector AB/11A
MCDU 2 Connector A/28 to FDIMU Connector AB/11B
MCDU 2 Connector A/11 to FDIMU Connector AA/11E
MCDU 2 Connector A/12 to FDIMU Connector AA/11F
- replace the FDIMU (10TV) AMM 31-36-34-000-002 and AMM 31-36-34-400-002.
B. Do the test given in Para. 3.