W DOC AIRBUS | TSM A320F

FDIMU Receives No Data from MCDU 1 or MCDU 2


TASK 31-36-00-810-918-A
FDIMU Receives No Data from MCDU 1 or MCDU 2


1. Possible Causes
  • wiring
  • MCDU-1 [3CA1]
  • MCDU-2 [3CA2]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-70-00-710-001
Operational Test of the Multipurpose Control and Display Unit (MCDU)
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
ASM 313601
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
3. Fault Confirmation
Subtask 31-36-00-740-208-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 11CA1, 11CA2 on the panel 121VU and 11CA1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-132-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • MCDU1 (3CA1) / FDIMU (10TV)
  • MCDU2 (3CA2) / FDIMU (10TV)

   (1) Do the operational test of the Flight Management System AMM 22-70-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the MCDU-1 [3CA1] or MCDU-2 [3CA2] to the DMU/FDIU (FDIMU) [10TV] ASM 313601:

    MCDU 1 Connector A/27 to FDIMU Connector AA/11A
    MCDU 1 Connector A/28 to FDIMU Connector AA/11B
    MCDU 1 Connector A/11 to FDIMU Connector AA/11E
    MCDU 1 Connector A/12 to FDIMU Connector AA/11F
    or
    MCDU 2 Connector A/27 to FDIMU Connector AB/11A
    MCDU 2 Connector A/28 to FDIMU Connector AB/11B
    MCDU 2 Connector A/11 to FDIMU Connector AA/11E
    MCDU 2 Connector A/12 to FDIMU Connector AA/11F

   (3) If the fault continues:
Subtask 31-36-00-740-209-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:07 UTC