FDIMU Receives No Data from the ACARS-MU or ATSU


TASK 31-36-00-810-916-A
FDIMU Receives No Data from the ACARS-MU or ATSU


1. Possible Causes
  • wiring
  • ATSU [1TX1]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
ASM 313605
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
AMM 46-21-00-710-001
Operational Test of the ATSU
3. Fault Confirmation
Subtask 31-36-00-740-204-B ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 5TX1 on the panel 121VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-130-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • ATSU (1TX1) / FDIMU (10TV)

   (1) Do the operational test of the ATSU AMM 46-21-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the ATSU [1TX1] to the DMU/FDIU (FDIMU) [10TV] ASM 313605:

    ATSU Connector AA/1E to FDIMU Connector AB/5J
    ATSU Connector AA/1F to FDIMU Connector AB/5K
    ATSU Connector AB/8A to FDIMU Connector AB/11J
    ATSU Connector AB/8B to FDIMU Connector AB/11K

   (3) If the fault continues:
Subtask 31-36-00-740-205-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.