TASK 31-36-00-810-912-A
FDIMU Receives No Data from the FQU


1. Possible Causes
  • wiring
  • FQIC [3QT]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 28-42-00-740-001
Status Report (BITE)
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
ASM 313701
3. Fault Confirmation
Subtask 31-36-00-740-198-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 2QT, 8QT on the panel 121VU and 1QT on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-127-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • FQU (3QT) / FDIMU (10TV)

   (1) Do the BITE test of the fuel quantity indicating computer AMM 28-42-00-740-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the FQIC [3QT] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:

    Fuel (FQU) Connector AB/4F to FDIMU Connector AA/2G
    Fuel (FQU) Connector AB/5F to FDIMU Connector AA/2H
    Fuel (FQU) Connector AB/6F to Ground

   (3) If the fault continues:
Subtask 31-36-00-740-199-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.