W DOC AIRBUS | TSM A320F

FDIMU Receives No Data from the DMC 1 or DMC 2


TASK 31-36-00-810-910-A
FDIMU Receives No Data from the DMC 1 or DMC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
ASM 313701
AMM 31-60-00-710-001
Operational Test of the EIS
3. Fault Confirmation
Subtask 31-36-00-740-192-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 10WT2, 21WT2 on the panel 121VU and 10WT1, 21WT1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-124-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • DMC1 (1WT1) / FDIMU (10TV) or
  • DMC2 (1WT2) / FDIMU (10TV)

   (1) Do the operational test of the electronic instrument system AMM 31-60-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the DMC-1 [1WT1] or DMC-2 [1WT2] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:

    DMC 1 Connector AB/1E to FDIMU Connector AA/6C
    DMC 1 Connector AB/1F to FDIMU Connector AA/6D
    or
    DMC 2 Connector AB/1E to FDIMU Connector AB/6C
    DMC 2 Connector AB/1F to FDIMU Connector AB/6D

   (3) If the fault continues:
Subtask 31-36-00-740-193-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:06 UTC