W DOC AIRBUS | TSM A320F

FDIMU Receives No Data from the CFDS


TASK 31-36-00-810-908-A
FDIMU Receives No Data from the CFDS


1. Possible Causes
  • wiring
  • CFDIU [1TW]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-740-002
BITE Test of the Centralized Fault Display Interface Unit (CFDIU)
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
ASM 313601
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
3. Fault Confirmation
Subtask 31-36-00-740-188-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 2TW, 8TW on the panel 121VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-122-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • CFDIU (1TW) / FDIMU (10TV)

   (1) Do the BITE test of the Central Fault Display Interface System (CFDIU) AMM 31-32-00-740-002.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the CFDIU [1TW] and the DMU/FDIU (FDIMU) [10TV] ASM 313601:

    CFDIU Connector AA/2B to FDIMU Connector AB/5C
    CFDIU Connector AA/2C to FDIMU Connector AB/5D
    CFDIU Connector AB/3F to FDIMU Connector AA/11E
    CFDIU Connector AB/3G to FDIMU Connector AA/11F
    CFDIU Connector AB/11D to FDIMU Connector AB/4C
    CFDIU Connector AB/11E to FDIMU Connector AA/4D

   (3) If the fault continues:
Subtask 31-36-00-740-189-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:06 UTC