FDIMU Receives No Data from the GPWC


TASK 31-36-00-810-907-A
FDIMU Receives No Data from the GPWC


1. Possible Causes
  • wiring
  • GPWC [1WZ]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
ASM 313701
AMM 34-48-00-710-001
Operational Test of GPWS Ground Self-test Function
3. Fault Confirmation
Subtask 31-36-00-740-186-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 2WZ, 3WZ on the panel 121VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-121-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • GPWC(1WZ) / FDIMU(10TV)

   (1) Do the operational test of the Ground Proximity Warning System AMM 34-48-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the GPWC [1WZ] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:

    GPWC Connector AB/1C to FDIMU Connector AA/5C
    GPWC Connector AB/1D to FDIMU Connector AA/5D

   (3) If the fault continues:
Subtask 31-36-00-740-187-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.