FDIMU Receives No Data from the FCDC 1 or FCDC 2


TASK 31-36-00-810-905-A
FDIMU Receives No Data from the FCDC 1 or FCDC 2


1. Possible Causes
  • wiring
  • FCDC-1 [3CE1]
  • FCDC-2 [3CE2]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-710-001
Operational Test of the FCDC
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
ASM 313701
3. Fault Confirmation
Subtask 31-36-00-740-182-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 20CE2 on the panel 121VU and 20CE1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-119-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • FCDC1 (3CE1) / FDIMU (10TV) or
  • FCDC2 (3CE2) / FDIMU (10TV)

   (1) Do the operational test of the FCDC AMM 27-96-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the FCDC-1 [3CE1] or FCDC-2 [3CE2] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:

    FCDC 1 Connector AA/5E to FDIMU Connector AA/3C
    FCDC 1 Connector AA/5F to FDIMU Connector AA/3D
    or
    FCDC 2 Connector AB/5E to FDIMU Connector AB/3C
    FCDC 2 Connector AB/5F to FDIMU Connector AB/3D

   (3) If the fault continues:
Subtask 31-36-00-740-183-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.