FDIMU Receives No Data from the FMGC 1 or FMGC 2
TASK 31-36-00-810-897-A
FDIMU Receives No Data from the FMGC 1 or FMGC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-172-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-114-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:05 UTC
FDIMU Receives No Data from the FMGC 1 or FMGC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-96-00-710-001 | Operational Test of the AFS |
| AMM 31-36-00-740-012 | Test of the Flight Data Interface and Management Unit (FDIMU) |
| AMM 31-36-34-000-002 | Removal of the FDIU/DMU (FDIMU) |
| AMM 31-36-34-400-002 | Installation of the FDIU/DMU (FDIMU) |
| ASM 313701 |
Subtask 31-36-00-740-172-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
4. Fault IsolationNOTE: Make sure that the circuit breakers 5TV, 10CA2 on the panel 121VU and 10CA1 on the panel 49VU are closed during the test.
Subtask 31-36-00-810-114-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
Subtask 31-36-00-740-173-A ** ON A/C NOT FOR ALL - FMCG1 (1CA1) / FDIMU (10TV), (Detailed message text: FMC BUS FAIL) or
- FMCG1 (1CA1) / FDIMU (10TV), (Detailed message text: FGC BUS FAIL) or
- FMCG2 (1CA2) / FDIMU (10TV), (Detailed message text: FMC BUS FAIL) or
- FMCG2 (1CA2) / FDIMU (10TV), (Detailed message text: FGC BUS FAIL)
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the FMGC-1 [1CA1] or FMGC-2 [1CA2] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:
FMGC 1 Connector AB/10A to FDIMU Connector AA/1E
FMGC 1 Connector AB/10B to FDIMU Connector AA/1F
FMGC 1 Connector AB/12A to FDIMU Connector AA/7C
FMGC 1 Connector AB/12B to FDIMU Connector AA/7D
or
FMGC 2 Connector AB/10A to FDIMU Connector AB/1E
FMGC 2 Connector AB/10B to FDIMU Connector AB/1F
FMGC 2 Connector AB/12A to FDIMU Connector AB/7C
FMGC 2 Connector AB/12B to FDIMU Connector AB/7D
- replace the FDIMU (10TV) AMM 31-36-34-000-002 and AMM 31-36-34-400-002.
B. Do the test given in Para. 3.