FDIMU Receives No Data from the LGCIU 1 or LGCIU 2
TASK 31-36-00-810-896-A
FDIMU Receives No Data from the LGCIU 1 or LGCIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-170-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-113-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:05 UTC
FDIMU Receives No Data from the LGCIU 1 or LGCIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-36-00-740-012 | Test of the Flight Data Interface and Management Unit (FDIMU) |
| AMM 31-36-34-000-002 | Removal of the FDIU/DMU (FDIMU) |
| AMM 31-36-34-400-002 | Installation of the FDIU/DMU (FDIMU) |
| ASM 313701 | |
| AMM 32-69-00-740-001 | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
Subtask 31-36-00-740-170-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
4. Fault IsolationNOTE: Make sure that the circuit breakers 5TV, 2GA, 52GA on the panel 121VU and 1GA on the panel 49VU are closed during the test.
Subtask 31-36-00-810-113-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
Subtask 31-36-00-740-171-A ** ON A/C NOT FOR ALL - LGCIU1 (5GA1)/FDIMU (10TV) or
- LGCIU2 (5GA2)/FDIMU (10TV)
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the LGCIU-1 [5GA1] or LGCIU-2 [5GA2] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:
LGCIU 1 Connector AA/13K to FDIMU Connector AA/1C
LGCIU 1 Connector AA/15K to FDIMU Connector AA/1D
or,
LGCIU 2 Connector AA/13K to FDIMU Connector AB/1C
LGCIU 2 Connector AA/15K to FDIMU Connector AB/1D
- replace the FDIMU (10TV) AMM 31-36-34-000-002 and AMM 31-36-34-400-002.
B. Do the test given in Para. 3.