W DOC AIRBUS | TSM A320F

FDIMU Receives No Data from the LGCIU 1 or LGCIU 2


TASK 31-36-00-810-896-A
FDIMU Receives No Data from the LGCIU 1 or LGCIU 2


1. Possible Causes
  • wiring
  • LGCIU-1 [5GA1]
  • LGCIU-2 [5GA2]
  • DMU/FDIU (FDIMU) [10TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-740-012
Test of the Flight Data Interface and Management Unit (FDIMU)
AMM 31-36-34-000-002
Removal of the FDIU/DMU (FDIMU)
AMM 31-36-34-400-002
Installation of the FDIU/DMU (FDIMU)
ASM 313701
AMM 32-69-00-740-001
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Fault Confirmation
Subtask 31-36-00-740-170-A ** ON A/C NOT FOR ALL
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) AMM 31-36-00-740-012.
NOTE: Make sure that the circuit breakers 5TV, 2GA, 52GA on the panel 121VU and 1GA on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-113-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • LGCIU1 (5GA1)/FDIMU (10TV) or
  • LGCIU2 (5GA2)/FDIMU (10TV)

   (1) Do the BITE test of the landing gear AMM 32-69-00-740-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the LGCIU-1 [5GA1] or LGCIU-2 [5GA2] and the DMU/FDIU (FDIMU) [10TV] ASM 313701:

    LGCIU 1 Connector AA/13K to FDIMU Connector AA/1C
    LGCIU 1 Connector AA/15K to FDIMU Connector AA/1D
    or,
    LGCIU 2 Connector AA/13K to FDIMU Connector AB/1C
    LGCIU 2 Connector AA/15K to FDIMU Connector AB/1D

   (3) If the fault continues:
Subtask 31-36-00-740-171-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:05 UTC