1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-160-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-107-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-740-161-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:05 UTC
DMU PCMCIA Media
1. Possible Causes
- DMU [1TV]
- PCMCIA Card
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-36-00-000-001 | Removal of the Personal Computer Memory Card (PCMCIA) of the FDIMU/DMU |
| AMM 31-36-00-400-001 | Installation of the Personal Computer Memory Card (PCMCIA) of the FDIMU/DMU |
| AMM 31-36-00-710-001 | Test of the DMU |
| AMM 31-36-34-000-001 | Removal of the Data Management Unit (DMU) |
| AMM 31-36-34-400-001 | Installation of the Data Management Unit (DMU) |
Subtask 31-36-00-740-160-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
(1) If the Result Power Up Test Page shows these messages, replace the DMU [1TV] AMM 31-36-34-000-001 and AMM 31-36-34-400-001:
4. Fault Isolation(1) If the Result Power Up Test Page shows these messages, replace the DMU [1TV] AMM 31-36-34-000-001 and AMM 31-36-34-400-001:
- EPROM I/O FAILURE (CPU1). . . . . . . . I . . .2
- SRAM FAILURE (CPU1). . . . . . . . . . .I . . .2
- FLASH PROM FAIL (CPU1). . . . . . . . . I . . .2
- ACQUI. BUS INTERFACE. . . . . . . . . . I . . .2
- DIAL. BUS INTERFACE. . . . . . . . . . .I . . .2
- EEPROM FAILURE (CPU1). . . . . . . . . .I . . .2
- INVALID OP SOFT. . . . . . . . . . . . .I . . .2
- CPU1/CPU2 SYNCHRO. . . . . . . . . . . .I . . .2
- EPROM FAILURE (CPU2). . . . . . . . . . I . . .2
- SRAM FAILURE (CPU2). . . . . . . . . . .I . . .2
- FLASH PROM FAIL (CPU2). . . . . . . . . I . . .2
- SAR MEMORY FAILURE. . . . . . . . . . . I . . .2
- DAR EMISSION FAILUR. . . . . . . . . . .I . . .2
- CPU1/CPU2 SYNC. FAILURE. . . . . . . . .I . . .2
- POWER SUPPLY ALARM. . . . . . . . . . . I . . .2
- INVALID OP. SOFTWARE. . . . . . . . . . I . . .3
- INVALID DATABASE. . . . . . . . . . . . I . . .3
Subtask 31-36-00-810-107-A ** ON A/C NOT FOR ALL
A. If the DMU (1TV) test shows the maintenance message DMU PCMCIA MEDIA (1TV) only:
5. Close-up- on the MCDU get access to the CFDS Trouble Shooting Page of the DMU (MCDU MENU / CFDS / INST / DMU / TROUBLE SHOOTING DATA).
- print out (PRINT) or notice the Trouble Shooting Data.
NOTE: For further work on the PCMCIA card you can find following messages under the topic DETAILED REASON on the TROUBLE SHOOTING DATA page:
* Invalid PCMCIA Media inserted
* Disk Formate Error
* Disk Access Error
* No Disk inserted (#)
* Disk full (#)
((#) if enabled through GSE).
* Invalid PCMCIA Media inserted
* Disk Formate Error
* Disk Access Error
* No Disk inserted (#)
* Disk full (#)
((#) if enabled through GSE).
- replace the PCMCIA Card AMM 31-36-00-000-001 AMM 31-36-00-400-001 .
Subtask 31-36-00-740-161-A ** ON A/C NOT FOR ALL
A. Do the test given in paragraph 3.A. again to make sure that the system operates
correctly (no maintenance message display).