W DOC AIRBUS | TSM A320F

DMU Receives No Data from the BSCU 1 or BSCU 2


TASK 31-36-00-810-890-A
DMU Receives No Data from the BSCU 1 or BSCU 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
AMM 32-42-00-710-001
Operational Check of the Normal Braking System
3. Fault Confirmation
Subtask 31-36-00-740-154-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 5CC2, 14CC2 on the panel 121VU and 5CC1, 14CC1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-104-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO BSCU 1 DATA, or
  • NO BSCU 2 DATA

   (1) Do the operational test of the Normal Braking System AMM 32-42-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
   (3) If the fault continues:
Subtask 31-36-00-740-155-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:04 UTC