W DOC AIRBUS | TSM A320F

DMU Receives No Data from the ACARS-MU or ATSU


TASK 31-36-00-810-835-A
DMU Receives No Data from the ACARS-MU or ATSU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-001
Test of the DMU
ASM 313605
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
AMM 46-21-00-710-001
Operational Test of the ATSU
3. Fault Confirmation
Subtask 31-36-00-740-096-B ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 1TX1 on the panel 121VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-075-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO ACARS DATA, or
  • ACARS COMMUNIC FAIL

   (1) Do the operational test of the ATSU AMM 46-21-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the ATSU [1TX1] to the DMU [1TV] ASM 313605:

    ATSU Connector AA/1E to DMU Connector AB/5J
    ATSU Connector AA/1F to DMU Connector AB/5K
    ATSU Connector AB/8A to DMU Connector AB/11J
    ATSU Connector AB/8B to DMU Connector AB/11K

   (3) If the fault continues:
Subtask 31-36-00-740-097-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.