DMU Receives No Data from the SFCC 1 or SFCC 2
TASK 31-36-00-810-833-A
DMU Receives No Data from the SFCC 1 or SFCC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-092-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-073-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:04 UTC
DMU Receives No Data from the SFCC 1 or SFCC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-54-00-710-001 | Operational Test of the Flap System |
| AMM 31-36-00-710-001 | Test of the DMU |
| AMM 31-36-34-000-001 | Removal of the Data Management Unit (DMU) |
| AMM 31-36-34-400-001 | Installation of the Data Management Unit (DMU) |
| ASM 313701 |
Subtask 31-36-00-740-092-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
4. Fault IsolationNOTE: Make sure that the circuit breakers 1TV, 7CV, 8CV, 11CV, 12CV, 2CN on the panel 121VU and 1CN, 5CV, 6CV on the panel 49VU and 9CV, 10CV on the panel 122VU are closed during the test.
Subtask 31-36-00-810-073-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
Subtask 31-36-00-740-093-A ** ON A/C NOT FOR ALL - NO SFCC 1 DATA, or
- NO SFCC 2 DATA
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
- do a check and repair the wiring from the SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] to the DMU [1TV] ASM 313701:
SFCC 1 Connector AB/4E to DMU Connector AA/3A
SFCC 1 Connector AB/4F to DMU Connector AA/3B
SFCC 2 Connector AB/4E to DMU Connector AB/3A
SFCC 2 Connector AB/4F to DMU Connector AB/3B
- replace the DMU (1TV) AMM 31-36-34-000-001 and AMM 31-36-34-400-001.
B. Do the test given in Para. 3.