DMU Receives No Data from the FQIC


TASK 31-36-00-810-832-A
DMU Receives No Data from the FQIC


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 28-42-00-740-001
Status Report (BITE)
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
3. Fault Confirmation
Subtask 31-36-00-740-090-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 2QT, 8QT on the panel 121VU and 1QT on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-072-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO FQI DATA

   (1) Do the BITE test of the Fuel Quantity Indicating Computer AMM 28-42-00-740-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the FQIC [3QT] to the DMU [1TV] ASM 313701:

    FQIC Connector AB/4F to DMU Connector AA/2G
    FQIC Connector AB/5F to DMU Connector AA/2H
    FQIC Connector AB/6F to Ground

   (3) If the fault continues:
Subtask 31-36-00-740-091-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.