DMU Receives No Data from the DMC 1 or DMC 2


TASK 31-36-00-810-829-A
DMU Receives No Data from the DMC 1 or DMC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
AMM 31-60-00-710-001
Operational Test of the EIS
3. Fault Confirmation
Subtask 31-36-00-740-084-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 10WT2, 21WT2 on the panel 121VU and 10WT1, 21WT1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-069-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO DMC 1 DATA, or
  • NO DMC 2 DATA

   (1) Do the operational test of the Electronic Instrument System AMM 31-60-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the DMC-1 [1WT1] or DMC-2 [1WT2] to the DMU [1TV] ASM 313701:

    DMC 1 Connector AB/1E to DMU Connector AA/6C
    DMC 1 Connector AB/1F to DMU Connector AA/6D
    or
    DMC 2 Connector AB/1E to DMU Connector AB/6C
    DMC 2 Connector AB/1F to DMU Connector AB/6D

   (3) If the fault continues:
Subtask 31-36-00-740-085-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.