DMU Receives No Data from the FWC 1 or FWC 2


TASK 31-36-00-810-828-A
DMU Receives No Data from the FWC 1 or FWC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
3. Fault Confirmation
Subtask 31-36-00-740-082-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 2WW on the panel 121VU and 3WW on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-068-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO FWC 1 DATA, or
  • NO FWC 2 DATA

   (1) Do the operational test of the Central Warning System AMM 31-50-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the FWC-1 [1WW1] or FWC-2 [1WW2] to the DMU [1TV] ASM 313701:

    FWC 1 Connector AB/12J to DMU Connector AA/6A
    FWC 1 Connector AB/12K to DMU Connector AA/6B
    or
    FWC 2 Connector AB/12J to DMU Connector AB/6A
    FWC 2 Connector AB/12K to DMU Connector AB/6B

   (3) If the fault continues:
Subtask 31-36-00-740-083-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.