TASK 31-36-00-810-827-A
DMU Receives No Data from the CFDS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-740-080-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-810-067-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:04 UTC
DMU Receives No Data from the CFDS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-740-002 | BITE Test of the Centralized Fault Display Interface Unit (CFDIU) |
| AMM 31-36-00-710-001 | Test of the DMU |
| ASM 313601 | |
| AMM 31-36-34-000-001 | Removal of the Data Management Unit (DMU) |
| AMM 31-36-34-400-001 | Installation of the Data Management Unit (DMU) |
Subtask 31-36-00-740-080-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
4. Fault IsolationNOTE: Make sure that the circuit breakers 1TV, 2TW, 8TW on the panel 121VU are closed during the test.
Subtask 31-36-00-810-067-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
Subtask 31-36-00-740-081-A ** ON A/C NOT FOR ALL - NO CDFS DATA, or
- CFDS COMMUNIC FAIL
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.
(2) If the fault continues:
- do a check and repair the wiring from the CFDIU [1TW] to the DMU [1TV] ASM 313601:
CFDIU Connector AA/2B to DMU Connector AB/5C
CFDIU Connector AA/2C to DMU Connector AB/5D
CFDIU Connector AB/3F to DMU Connector AA/11E
CFDIU Connector AB/3G to DMU Connector AA/11F
- replace the DMU (1TV) AMM 31-36-34-000-001 and AMM 31-36-34-400-001.
B. Do the test given in Para. 3.