DMU Receives No Data from the FCU


TASK 31-36-00-810-825-A
DMU Receives No Data from the FCU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
3. Fault Confirmation
Subtask 31-36-00-740-076-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 9CA2 on the panel 121VU and 9CA1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-065-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO FCU BUS A DATA, or
  • NO FCU BUS B DATA, or
  • NO FCU 1 DATA, or
  • NO FCU 2 DATA

   (1) Do the operatioal test of the AFS AMM 22-96-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the FCU [2CA] to the DMU [1TV] ASM 313701:

    FCU Connector A/DD to DMU Connector AA/5A
    FCU Connector A/EE to DMU Connector AA/5B
    FCU Connector A/FF to DMU Connector AB/5A
    FCU Connector A/GG to DMU Connector AB/5B

   (3) If the fault continues:
Subtask 31-36-00-740-077-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.