DMU Receives No Data from the ECB


TASK 31-36-00-810-823-A
DMU Receives No Data from the ECB


1. Possible Causes
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
  • DMU [1TV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
AMM 49-61-34-400-001
Installation of the Electronic Control Box (ECB) (GTCP 36-300)
3. Fault Confirmation
Subtask 31-36-00-740-072-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 1KD, 2KD on the panel 121VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-063-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO ECB DATA

   (1) Do the operational test of the CFDS after Removal/Installation of ECB AMM 49-61-34-400-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the ELECTRONIC CONTROL BOX [59KD] to the DMU [1TV] ASM 313701:

    ECB Connector AB/K8 to DMU Connector AB/2G
    ECB Connector AB/K9 to DMU Connector AB/2H
    ECB Connector AB/E10 to Ground

   (3) If the fault continues:
Subtask 31-36-00-740-073-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.