W DOC AIRBUS | TSM A320F

DMU Receives No Data from the FMGC 1 or FMGC 2


TASK 31-36-00-810-819-A
DMU Receives No Data from the FMGC 1 or FMGC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
ASM 313701
3. Fault Confirmation
Subtask 31-36-00-740-064-A ** ON A/C NOT FOR ALL
A. Do the DMU (1TV) fault monitoring test AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1TV, 10CA1, 10CA2 on the panel 121VU and 10CA1 on the panel 49VU are closed during the test.
4. Fault Isolation
Subtask 31-36-00-810-059-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

  • NO FMGC-FMC 1 DATA, or
  • NO FMGC-FMC 2 DATA, or
  • NO FMGC-FGC 1 DATA, or
  • NO FMGC-FGC 2 DATA

   (1) Do the operational test of the Flight Data Management and Guidance System AMM 22-96-00-710-001.

     (a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 201.

   (2) If the fault continues:
  • do a check and repair the wiring from the FMGC-1 [1CA1] or FMGC-2 [1CA2] to the DMU [1TV] ASM 313701:

    FMGC 1 Connector AA/10A to DMU Connector AA/1E
    FMGC 1 Connector AA/10B to DMU Connector AA/1F
    FMGC 1 Connector AB/12A to DMU Connector AA/7C
    FMGC 1 Connector AB/12B to DMU Connector AA/7D
    or
    FMGC 2 Connector AB/10A to DMU Connector AB/1E
    FMGC 2 Connector AB/10B to DMU Connector AB/1F
    FMGC 2 Connector AB/12A to DMU Connector AA/7C
    FMGC 2 Connector AB/12B to DMU Connector AA/7D

   (3) If the fault continues:
Subtask 31-36-00-740-065-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:02 UTC