DAR Tape Low/Media Low
TASK 31-36-00-810-803-A
DAR Tape Low/Media Low
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-36-00-710-051-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-36-00-810-052-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:02 UTC
DAR Tape Low/Media Low
1. Possible Causes
- wiring
[2TV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-36-00-740-003 | Test of the DAR |
| ASM 313601 | |
| AMM 31-36-52-000-001 | Removal of the Digital AIDS Recorder (DAR) |
| AMM 31-36-52-400-001 | Installation of the Digital AIDS Recorder (DAR) |
Subtask 31-36-00-710-051-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-36-00-810-052-C ** ON A/C NOT FOR ALL
A. If the DAR (2TV) test gives the maintenance message MEDIA LOW:
Subtask 31-36-00-710-053-A ** ON A/C NOT FOR ALL - do a check of the wiring ASM 313601, between:
DAR (2TV) connector AA/5G and DMU (1TV) connector AB/13E
and repair the wiring if necessary.
- replace the
[2TV] AMM 31-36-52-000-001 and AMM 31-36-52-400-001.
B. Do the test given in paragraph 3.A. again to check the correct operation
(no maintenance message display).
(no maintenance message display).