DMU receives no Data from the FDIU


TASK 31-33-00-810-823-A
DMU receives no Data from the FDIU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-33-00-710-006
Operational Check of DFDR via MCDU
ASM 313301
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
3. Fault Confirmation
Subtask 31-33-00-710-064-A ** ON A/C NOT FOR ALL
A. Do the test of the DMU AMM 31-36-00-710-001

NOTE: make sure that the circuit breakers 7TU and 4TV are closed.

4. Fault Isolation
Subtask 31-33-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenace message NO FDIU DATA:
   (1) If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check and repair the wiring between:
    FDIU [2TU] AB/9J and DMU [1TV] AA/5E,
    FDIU [2TU] AB/9K and DMU [1TV] AA5F ASM 313301.
Subtask 31-33-00-710-065-A ** ON A/C NOT FOR ALL
B. Do the test as given in Para. 3 again to check the correct operation
(no maintenace message display).