W DOC AIRBUS | TSM A320F

Access to the #quot#On Ground#quot# CFDS Menu Not Available on the Ground


TASK 31-32-00-810-949-A
Access to the "On Ground" CFDS Menu Not Available on the Ground


1. Possible Causes
  • wiring
  • CFDIU [1TW]
  • RELAY-A/C ON GND [95CV]
  • RELAY-A/C ON GND [97CV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2046500
AMM 31-32-00-860-001
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
ASM 313203
AWM 313215
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-184-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
121VUEIS/FWC2/SPLY2WWQ07
121VULGCIU/BAT SPLY/SYS158GAR32
Subtask 31-32-00-700-051-A
B. On the CFDS MENU page, get access to the SYSTEM REPORT/TEST page AMM 31-32-00-860-001.
   (1) If the access to the SYSTEM REPORT/TEST page is not possible, go to the Para. Fault Isolation.
4. Fault Isolation
Subtask 31-32-00-810-205-A
A. If there is confirmation of the fault:
   (1) Do a check and repair if necessary the wiring from CFDIU (1TW) pins AB/5F, 5G to the FWC2 (1WW2) pins AB/12J, 12K ASM 313203.
   (2) If the fault continues:
     (a) Do a check and repair if necessary the wiring from the CFDIU (1TW) pin AA/1H to the LGCIU1 (5GA1) pin AB/15C AWM 313215.
   (3) If the fault continues:
     (a) Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
   (4) If the fault continues:
     (a) Replace the RELAY-A/C ON GND [95CV] ESPM 2046500.
   (5) If the fault continues:
     (a) Replace the RELAY-A/C ON GND [97CV] ESPM 2046500.
Subtask 31-32-00-740-325-A
B. Do the test given in para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:59 UTC