Access to the #quot#On Ground#quot# CFDS Menu Not Available on the Ground
TASK 31-32-00-810-949-A
Access to the "On Ground" CFDS Menu Not Available on the Ground
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-184-A
Subtask 31-32-00-810-205-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:59 UTC
Access to the "On Ground" CFDS Menu Not Available on the Ground
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2046500 | |
| AMM 31-32-00-860-001 | Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page |
| ASM 313203 | |
| AWM 313215 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-184-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-700-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R32 |
B. On the CFDS MENU page, get access to the SYSTEM REPORT/TEST page AMM 31-32-00-860-001.
(1) If the access to the SYSTEM REPORT/TEST page is not possible, go to the Para. Fault Isolation.
4. Fault Isolation(1) If the access to the SYSTEM REPORT/TEST page is not possible, go to the Para. Fault Isolation.
Subtask 31-32-00-810-205-A
A. If there is confirmation of the fault:
(1) Do a check and repair if necessary the wiring from CFDIU (1TW) pins AB/5F, 5G to the FWC2 (1WW2) pins AB/12J, 12K ASM 313203.
(2) If the fault continues:
(a) Do a check and repair if necessary the wiring from the CFDIU (1TW) pin AA/1H to the LGCIU1 (5GA1) pin AB/15C AWM 313215.
(3) If the fault continues:
(a) Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
(4) If the fault continues:
(a) Replace the RELAY-A/C ON GND [95CV] ESPM 2046500.
(5) If the fault continues:
(a) Replace the RELAY-A/C ON GND [97CV] ESPM 2046500.
Subtask 31-32-00-740-325-A (1) Do a check and repair if necessary the wiring from CFDIU (1TW) pins AB/5F, 5G to the FWC2 (1WW2) pins AB/12J, 12K ASM 313203.
(2) If the fault continues:
(a) Do a check and repair if necessary the wiring from the CFDIU (1TW) pin AA/1H to the LGCIU1 (5GA1) pin AB/15C AWM 313215.
(3) If the fault continues:
(a) Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
(4) If the fault continues:
(a) Replace the RELAY-A/C ON GND [95CV] ESPM 2046500.
(5) If the fault continues:
(a) Replace the RELAY-A/C ON GND [97CV] ESPM 2046500.
B. Do the test given in para. 3.B.