W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by RMP3


TASK 31-32-00-810-948-A
Failure of the CFDIU Detected by RMP3


1. Possible Causes
  • CFDIU [1TW]
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-00-740-001
BITE Test of the Radio Management
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-740-323-A
A. Test
Do the BITE test of RMP3 AMM 23-13-00-740-001.
4. Fault Isolation
Subtask 31-32-00-810-204-A
A. If the test gives the maintenance message RMP3 : NO DATA FROM CFDIU:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check and repair the wiring from CFDIU (1TW) pins AA/2B, 2C to the first terminal block, ASM 313202.
  • Do a check and repair the wiring from RMP1 (1RG1) pins A/BB, CC to RMP3 (1RG3) pins A/x, y, ASM 231301.
Subtask 31-32-00-740-324-A
B. Do the test given in para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:59 UTC