W DOC AIRBUS | TSM A320F

Loss of the Output Bus from the CSAS to the CFDIU


TASK 31-32-00-810-943-A
Loss of the Output Bus from the CSAS to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • CSAS CONTROL UNIT [100HW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-58-34-000-001
Removal of the CSAS Control Unit
AMM 21-58-34-400-001
Installation of the CSAS Control Unit
AMM 31-32-00-740-009
Read the AVIONICS STATUS on the MCDU
ASM 313206
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-179-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUCSAS / CTLR1HWU17
Subtask 31-32-00-740-315-A ** ON A/C NOT FOR ALL
B. Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
4. Fault Isolation
Subtask 31-32-00-810-197-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO CSAS DATA:
   (1) If the fault continues:
     (a) If the fault continues:
  • Do a check and repair the wiring from the CFDIU (1TW) pins AB/13A, 13B to the CSAS CONTROL UNIT (100HW) ASM 313206.
Subtask 31-32-00-740-316-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.