Failure of the CFDIU
TASK 31-32-00-810-937-A
Failure of the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-310-A 4. Fault Isolation
Subtask 31-32-00-810-188-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:59 UTC
Failure of the CFDIU
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-740-009 | Read the AVIONICS STATUS on the MCDU |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| ASM 462106 |
Subtask 31-32-00-740-310-A 4. Fault Isolation
Subtask 31-32-00-810-188-A
A. If the test gives the maintenance message NO ATSU DATA:
(1) replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
(2) If the fault continues:
do a check and repair the wiring from the CFDIU (1TW) pins AB/9B, 9C to the first terminal block ASM 462106.
Subtask 31-32-00-869-051-A (1) replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
(2) If the fault continues:
do a check and repair the wiring from the CFDIU (1TW) pins AB/9B, 9C to the first terminal block ASM 462106.
B. Do the test given in Para. 3.B.