W DOC AIRBUS | TSM A320F

Loss of the BUS from the Multipurpose Disk Drive Unit (MDDU) to the CFDIU


TASK 31-32-00-810-936-A
Loss of the BUS from the Multipurpose Disk Drive Unit (MDDU) to the CFDIU


1. Possible Causes
  • MDDU
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-740-009
Read the AVIONICS STATUS on the MCDU
ASM 313801
AMM 31-38-22-000-001
Removal of the MDDU
AMM 31-38-22-400-001
Installation of the MDDU
3. Fault Confirmation
Subtask 31-32-00-865-168-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUDATA/LOADER/SPLY3TDJ16
** ON A/C NOT FOR ALL
121VUDLS&/DLRB/SPLY5TDJ15
Subtask 31-32-00-710-063-A ** ON A/C NOT FOR ALL
B. Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
4. Fault Isolation
Subtask 31-32-00-810-187-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO MDDU DATA:

   (1) Replace the MDDU AMM 31-38-22-000-001 and AMM 31-38-22-400-001.
   (2) If the fault continues:

  • Do a check and repair the wiring between the MDDU plug connector and the CFDIU (1TW) ASM 313801:

  • Pin A/24, 25 to pin AA/9F, 9G (1TW).

  • Pin A/12,13 to pin AA/11F, 11G (1TW).
Subtask 31-32-00-810-187-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO MDDU DATA:

   (1) Do a check and repair the wiring between the connector (2TD) and the CFDIU (1TW) ASM 313801:

  • Pin A/24, 25 to pin AA/9F, 9G (1TW).

  • Pin A/12, 13 to pin AA/11F, 11G (1TW).
Subtask 31-32-00-710-064-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:59 UTC