Failure of the MCDU3
TASK 31-32-00-810-922-A
Failure of the MCDU3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-288-A 4. Fault Isolation
Subtask 31-32-00-810-171-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:58 UTC
Failure of the MCDU3
1. Possible Causes
- MCDU-3 [3CA3]
RELAY-L/G POSITION, SYS1 (11GB) - LGCIU-1 [5GA1]
- RELAY-GND SERVICE BUS CHG OVER [53GA]
- wiring
- C/B-DUMMY CB [11CA3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-82-12-000-001 | Removal of the MCDU |
| AMM 22-82-12-400-002 | Installation of the MCDU |
| ASM 228402 | |
| AMM 31-32-00-740-003 | Ground Scanning of the CFDIU |
| ASM 323105 | |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| ASM 326201 |
Subtask 31-32-00-740-288-A 4. Fault Isolation
Subtask 31-32-00-810-171-A
A. If the test gives the maintenance message MCDU3 and the circuit breaker (11CA3) is closed:
Subtask 31-32-00-810-172-A - do a check for 115VAC at the MCDU3 (3CA3).
- replace the MCDU-3 [3CA3] AMM 22-82-12-000-001 and AMM 22-82-12-400-002.
- replace the
RELAY-L/G POSITION, SYS1 (11GB) .
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- replace the RELAY-GND SERVICE BUS CHG OVER [53GA] .
- do a check of the wiring from the relay (11GB):
. pin A/C1 to MCDU3 (3CA3) pin A/40
. pin A/C2 to the circuit breaker (11CA3)
. pin A/X1 to relay (53GA) pin A/B2
. pin A/X2 to LGCIU (5GA1) pin AB/1.
* If there is no continuity:
repair the related wiring.
* If there is continuity:
replace the C/B-DUMMY CB [11CA3] ASM 228402 ASM 323105 ASM 326201.
B. If the test gives the maintenance message MCDU3 and the circuit breaker (11CA3) is open:
Subtask 31-32-00-740-289-A - close this circuit breaker.
- disconnect these two units:
MCDU3 (3CA3)
Relay (11GB) - close the circuit breaker (11CA3).
- connect the units one by one until the circuit breaker (11CA3) trips
- replace the related unit:
For the MCDU3 (3CA3) AMM 22-82-12-000-001 and AMM 22-82-12-400-002.
- do a check for a short to ground between the circuit breaker (11CA3) and the two units ASM 228402.
- repair the related wiring.
- replace the C/B-DUMMY CB [11CA3] .
C. Do the test given in Para. 3.