W DOC AIRBUS | TSM A320F

Loss of the MCDU 2 by the CFDIU


TASK 31-32-00-810-920-A
Loss of the MCDU 2 by the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-740-003
Ground Scanning of the CFDIU
ASM 313207
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-160-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/MCDU/211CA2N20
Subtask 31-32-00-740-284-A
B. Test
Do the GROUND SCANNING of the CFDIU AMM 31-32-00-740-003.
4. Fault Isolation
Subtask 31-32-00-810-169-A
A. If the test gives the maintenance message NO MCDU2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/3B, 3C to the first terminal block ASM 313207.
Subtask 31-32-00-740-285-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:58 UTC