Loss of the Output Bus of the Aft Cargo Compartment Heat Controller by the CFDIU
TASK 31-32-00-810-918-A
Loss of the Output Bus of the Aft Cargo Compartment Heat Controller by the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-280-A 4. Fault Isolation
Subtask 31-32-00-810-167-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:57 UTC
Loss of the Output Bus of the Aft Cargo Compartment Heat Controller by the CFDIU
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313202 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-740-280-A 4. Fault Isolation
Subtask 31-32-00-810-167-A
A. If the test gives the maintenance message NO AFT CHC DATA:
Subtask 31-32-00-740-281-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AA/5H, 5J to the first terminal block ASM 313202.
B. Do the test given in Para. 3.