Loss of the Bus Output from the RMP 1 to the CFDIU
TASK 31-32-00-810-911-A
Loss of the Bus Output from the RMP 1 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-153-A
Subtask 31-32-00-810-161-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:57 UTC
Loss of the Bus Output from the RMP 1 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 231302 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-153-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM/RMP/1 | 2RG1 | G10 |
B. Job Set-up
Make sure that only the ON/OFF switch on the RMP 1 is at ON.
Subtask 31-32-00-740-268-A 4. Fault IsolationMake sure that only the ON/OFF switch on the RMP 1 is at ON.
Subtask 31-32-00-810-161-A
A. If the test gives the maintenance message NO RMP1 DATA:
Subtask 31-32-00-740-269-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the wiring from CFDIU (1TW) pins AA/10D, 10E to RMP 1 (1RG1) pins A/<P, <Q ASM 231302.
B. Do the test given in Para. 3.C.