Loss of Data from the HF 1 Transceiver to the CFDIU
TASK 31-32-00-810-909-A
Loss of Data from the HF 1 Transceiver to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-151-A
Subtask 31-32-00-810-159-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:57 UTC
Loss of Data from the HF 1 Transceiver to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 231101 | |
| AMM 23-11-33-000-001 | Removal of the HF Transceiver |
| AMM 23-11-33-400-001 | Installation of the HF Transceiver |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-151-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-264-A ** ON A/C NOT FOR ALL Subtask 31-32-00-740-264-C ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM HF1 | 1RE1 | HA14 |
Subtask 31-32-00-810-159-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO HF1 DATA:
Subtask 31-32-00-740-265-A ** ON A/C NOT FOR ALL - replace the XCVR-HF, 1 [3RE1] AMM 23-11-33-000-001 and AMM 23-11-33-400-001.
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the HF 1 transceiver (3RE1) to the CFDIU (1TW) ASM 231101.
B. Do the test given in Para. 3.B.
Subtask 31-32-00-810-159-C ** ON A/C NOT FOR ALL C. If the test gives the maintenance message NO HF1 DATA:
Subtask 31-32-00-740-265-C ** ON A/C NOT FOR ALL - replace the XCVR-HF, 1 [3RE1] AMM 23-11-33-000-001 and AMM 23-11-33-400-001.
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the HF 1 transceiver (3RE1) to the CFDIU (1TW) ASM 231101.
D. Do the test given in Para. 3.B.