W DOC AIRBUS | TSM A320F

Loss of Data from the VHF 3 Transceiver to the CFDIU


TASK 31-32-00-810-905-A
Loss of Data from the VHF 3 Transceiver to the CFDIU


1. Possible Causes
  • XCVR-VHF, 3 [1RC3]
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 231203
AMM 23-12-33-000-001
Removal of the VHF Transceiver
AMM 23-12-33-400-001
Installation of the VHF Transceiver
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-147-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/VHF/32RC3L05
** ON A/C NOT FOR ALL
121VUCOM/VHF/32RC3L05
Subtask 31-32-00-740-256-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-155-A
A. If the test gives the maintenance message NO VHF3 DATA:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the VHF 3 transceiver (1RC3) to the CFDIU (1TW) ASM 231203.
Subtask 31-32-00-740-257-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:57 UTC