Failure of the CFDIU Detected by the LGCIU 2
TASK 31-32-00-810-904-A
Failure of the CFDIU Detected by the LGCIU 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-254-A 4. Fault Isolation
Subtask 31-32-00-810-154-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:57 UTC
Failure of the CFDIU Detected by the LGCIU 2
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 313205 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 32-69-00-740-001 | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
Subtask 31-32-00-740-254-A 4. Fault Isolation
Subtask 31-32-00-810-154-A
A. If the test gives the maintenance message LGCIU2 : NO DATA FROM CFDS:
Subtask 31-32-00-740-255-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AB/11D, 11E to the first terminal block ASM 313205.
B. Do the test given in Para. 3.