W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by the LGCIU 1


TASK 31-32-00-810-903-A
Failure of the CFDIU Detected by the LGCIU 1


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313204
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 32-69-00-740-001
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Fault Confirmation
Subtask 31-32-00-740-252-A
A. Test
Do the BITE test of the landing gear AMM 32-69-00-740-001.
4. Fault Isolation
Subtask 31-32-00-810-153-A
A. If the test gives the maintenance message LGCIU1 : NO DATA FROM CFDS:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/11F, 11G to the first terminal block ASM 313204.
Subtask 31-32-00-740-253-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:57 UTC