Loss of the PHC 3 Output Bus by the CFDIU
TASK 31-32-00-810-896-A
Loss of the PHC 3 Output Bus by the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-143-A
Subtask 31-32-00-810-146-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:56 UTC
Loss of the PHC 3 Output Bus by the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313206 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-143-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-238-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
Subtask 31-32-00-810-146-A
A. If the test gives the maintenance message NO PHC3 DATA:
Subtask 31-32-00-740-239-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the PHC-3 [6DA3] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- do a check and repair the
wiring from the CFDIU (1TW) to the PHC 3 (6DA3) from pins AB/2F, 2G to pins A/M, N ASM 313206.
B. Do the test given in Para. 3.B.