W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the EIU 2 to the CFDIU


TASK 31-32-00-810-892-A
Loss of the Bus Output from the EIU 2 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313205
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-138-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/ENG2/FADEC B/AND EIU 24KS2Q40
Subtask 31-32-00-740-228-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-141-A
A. If the test gives the maintenance message NO EIU 2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/13H, 13J to the first terminal block ASM 313205.
Subtask 31-32-00-740-229-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:56 UTC