Loss of the Output Bus from the CIDS Director 1 to the CFDIU
TASK 31-32-00-810-888-A
Loss of the Output Bus from the CIDS Director 1 to the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-134-A
Subtask 31-32-00-810-137-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:55 UTC
Loss of the Output Bus from the CIDS Director 1 to the CFDIU
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- CFDIU [1TW]
wiring from the CFDIU (1TW) to the CIDS director 1 (101RH)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 31-32-00-740-009 | Read the AVIONICS STATUS on the MCDU |
| ASM 313204 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-134-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-220-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M06 |
B. Test
(1) Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
(2) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
Subtask 31-32-00-740-220-B ** ON A/C NOT FOR ALL (1) Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
(2) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
B. Test
(1) Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
(2) Do the BITE test of the Cabin Intercommunication Data system through the CFDS AMM 23-73-00-740-005.
(3) Make sure that there is no INOP SYS, no MAINTENANCE STATUS or no ECAM warning related to the NO CIDS 1 DATA maintenance message.
4. Fault Isolation(1) Read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
(2) Do the BITE test of the Cabin Intercommunication Data system through the CFDS AMM 23-73-00-740-005.
(3) Make sure that there is no INOP SYS, no MAINTENANCE STATUS or no ECAM warning related to the NO CIDS 1 DATA maintenance message.
Subtask 31-32-00-810-137-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO CIDS 1 DATA and if the CIDS BITE test gives the CIDS1 (ACT.) menu:
Subtask 31-32-00-810-137-B ** ON A/C NOT FOR ALL - swap the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the CIDS director 1 (101RH) from pins AA/3F, 3G to pins AA/11A, 11B ASM 313204.
- replace the CIDS that you installed on side 2.
A. If the test gives the maintenance message NO CIDS 1 DATA and if the CIDS BITE test gives the CIDS1 (ACT.) menu:
Subtask 31-32-00-810-193-A - swap the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- read the AVIONICS STATUS on the MCDU AMM 31-32-00-740-009.
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the CIDS director 1 (101RH) from pins AA/3F, 3G to pins AA/11A, 11B ASM 313204.
- replace the CIDS that you installed on side 2.
B. If the test gives the maintenance message NO CIDS 1 DATA and if the CIDS BITE test gives the CIDS1 (PAS.) menu:
Subtask 31-32-00-740-221-A - replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the CIDS director 1 (101RH) from pins AA/3F, 3G to pins AA/11A, 11B ASM 313204.
C. Do the test given in Para. 3.B.