Loss of the Bus Output from the LGCIU 2 to the CFDIU


TASK 31-32-00-810-887-A
Loss of the Bus Output from the LGCIU 2 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • LGCIU-2 [5GA2]
  • wiring from the CFDIU (1TW) to the LGCIU 2 (5GA2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313205
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 31-32-00-865-133-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
Subtask 31-32-00-740-218-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-136-A
A. If the test gives the maintenance message NO LGCIU 2 DATA:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) to the LGCIU 2 (5GA2) from pins AB/7D, 7E to pins AA/13H, 15H ASM 313205.
Subtask 31-32-00-740-219-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:55 UTC