Loss of the Bus Output from the LGCIU 2 to the CFDIU
TASK 31-32-00-810-887-A
Loss of the Bus Output from the LGCIU 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-133-A
Subtask 31-32-00-810-136-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:55 UTC
Loss of the Bus Output from the LGCIU 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313205 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 31-32-00-865-133-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-218-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
Subtask 31-32-00-810-136-A
A. If the test gives the maintenance message NO LGCIU 2 DATA:
Subtask 31-32-00-740-219-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the LGCIU 2 (5GA2) from pins AB/7D, 7E to pins AA/13H, 15H ASM 313205.
B. Do the test given in Para. 3.B.