Loss of the Bus Output from the LGCIU 1 to the CFDIU


TASK 31-32-00-810-886-A
Loss of the Bus Output from the LGCIU 1 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • LGCIU-1 [5GA1]
  • wiring from the CFDIU (1TW) to the LGCIU 1 (5GA1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313204
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 31-32-00-865-132-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
Subtask 31-32-00-740-216-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-135-A
A. If the test gives the maintenance message NO LGCIU 1 DATA:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) to the LGCIU 1 (5GA1) from pins AA/7F, 7G to pins AA/13H, 15H ASM 313204.
Subtask 31-32-00-740-217-A
B. Do the test given in Para. 3.B.