Loss of the Bus Output from the DMC 2 to the CFDIU
TASK 31-32-00-810-877-A
Loss of the Bus Output from the DMC 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-125-A
Subtask 31-32-00-810-126-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:54 UTC
Loss of the Bus Output from the DMC 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-32-00-865-125-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-198-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/DMC2/SPLY | 10WT2 | Q08 |
| 121VU | EIS/DMC2/SWTG | 21WT2 | R08 |
Subtask 31-32-00-810-126-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO DMC 2 DATA:
Subtask 31-32-00-810-126-B ** ON A/C NOT FOR ALL - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the DMC 2 (1WT2) from pins AB/6F, 6G to pins AB/1C, 1D ASM 313203.
A. If the test gives the maintenance message NO DMC 2 DATA:
Subtask 31-32-00-740-199-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the DMC 2 (1WT2) from pins AB/6F, 6G to pins AD/13F, 13G ASM 313203.
B. Do the test given in Para. 3.B.